High speed handpiece maintenance procedures and precautions maintenance processes

1.clean water spraying holes: three holes clean water pipes and clean the probe with a three-hole jet,water jet clogging prevention;
2.Clean internal phone: Cleaners aligned phone tail,gently pressing 1 seconds,remove the dirt inside the phone;
3.the cleaning surface of the phone: the cleaner sprayed on a clean tissue,then gently wipe the surface of the phone;
4.lubrication head: There are two methods to choose from,recommend the first 1) plus grease: grease installed in accordance with the Canadian way of loading needle to the nose,then rotate refueling; please note that the new phone is rotated 360 degrees Old phone rotates 180 degrees,the use of lubricants,lubricating oil aligning phone tail pressing 1 seconds,then wipe with a clean paper towel.
5.the rotary bur: After refueling finished,the bur Replace the nose,the low speed of rotation 10-15 seconds; this allows the lubricant sufficiently uniform smear on the head inside; note that this work can also be After autoclaving conduct.
6.autoclavable: After the phone in the refueling autoclavable cabinet for disinfection,sterilization at 136 degrees for 10-30 minutes 2 atmospheres;
7.if there is no rotation of the bur After refueling,it is possible at this time to drive the needle Replace the phone at a low speed of rotation 10-15 seconds.



High speed handpiece maintenance:
1.refueling work must be done before autoclavable and not prior to use;
2.prohibit idling; easy to damage the collet;
3.try to use the latest clean lubricating product is not recommended the use of domestic products.If you use chlorine,hypochlorous acid and aqueous cleaning within the domestic lubricant,it will cause damage to the phone;
4.preventing the bump,or likely to influence the clamping device and bearing life,even the life of the phone;
5.the use of non-diameter requirements will cause bur clamping device failure (standard bur diameter 1.59-1.60 mm);
6.gas pressure and gas quality must comply with the requirements of the appropriate configuration for each phone.

Product details,please click: http://www.medicalequipment-msl.com/htm/dental-instrument/

Related Posts
Handpiece common problems and solutions
When portable handpiece have problems you need to check which problems like......
Dental anesthesia and local anesthesia
Dental anesthesia (or dental anaesthesia) is a field of anesthesia that includes not only local anesthetics but sedation and general anesthesia......

Tuesday, December 22, 2015

Ventilator Machine classification

Ventilator Machine,it is a kind of can take the place of,control or change people normal breathing,increased pulmonary ventilation,improve respiratory function,reduce power consumption,breathing device for managing cardiac reserve capacity.When infants complicated with acute respiratory failure,through positive conservative treatment is invalid,breathing and much sputum and thick,expectoration drainage difficulty,blocking the airway or atelectasis,consideration should be given endotracheal intubation and ventilator.Ventilator Machine must have four basic functions,namely to lung inflated,breathe in to out conversion,alveolar gas discharge and exhale to inhale conversion,cycle in turn.So there must be,conveying gas engine instead of the human body well.

Breathing machine categories:
1.According to the connection with the patient can be divided into:
Noninvasive ventilator:breathing machine,through the mask to connect with the patient.
Have a breathing machine:breathing machine through endotracheal intubation is connected to the patients.

buy Ventilator Machine

2.According to use classification:
Emergency breathing machine:special field first aid.
Breath therapy ventilation machine:for a long time in patients with respiratory insufficiency ventilatory support and respiratory therapy.
Anesthesia ventilator:dedicated to anesthesia breathing management.
Pediatric respiratory machine:special without and newborn ventilatory support and respiratory therapy.
High frequency respirator:have ventilatory frequency > 60 times/min.
Noninvasive ventilator:through the mask or nasal mask ventilation support.

3.According to the drive way classification:
Pneumatic pneumatic ventilator,air supply and control system are only powered by oxygen source.Portable emergency breathing machine.

4.According to the ventilation pattern classification (four categories):
Regular ventilation machine (time switch):according to the preset time exhaling and inhaling complete conversion.
Constant volume ventilation machine (capacity switch):complete inhalation and exhalation conversion as the default output volume.
Constant pressure ventilation machine (pressure switch):according to the preset exhaling and inhaling airway pressure value to complete transformation.
Circulation of qi activity (flow switch):according to the preset exhaling and inhaling gas velocity value complete transformation.

Our Guangzhou Medsinglong Medical Equipment Co., Ltd is specialized in doing Ventilator Machine manufacturers,if you have any questions,you can contact us:cindy@medicalequipment-msl.com

Related Posts
The Function of Medical Ventilator
Ventilator is a tool to implement mechanical ventilation......
What Is a Ventilator
A ventilator (VEN-til-a-tor) is a machine that supports breathing......

Tuesday, December 15, 2015

Advantages Argon knife treatment

In view of the laser,high-frequency electric burn treatment endobronchial operations have some risk and can lead to some serious complications.In recent years,a new coagulation technology-argon plasma coagulation (Argon plasma coagulation,APC),commonly known as argon knife,began in the field of application of breathing,the country has a number of units to carry out,in fact,the technology in 1991 namely the introduction of endoscopic treatment Grund,and has accumulated a lot of experience in the field of digestive endoscopy.



Argon knife advantages:
1.Effective,safe,non-contact,to avoid blocking the probe caused by exposure treatment;
2.Limited depth of coagulation,typically 0.5-3.0mm (1/3 of a high-frequency electric knife),less prone to perforation,a large area quickly stop the bleeding,reduce operating time,argon arc uniform,dense,uniform solid scab formation also;
3.No damage to metal stents (high-frequency electric knife treatment may be due to metal stents cause leakage,Nd: YAG laser can damage the scaffold);
4.Fewer smog,good vision,means lightweight,easy to operate,low cost,economic savings,etc.,is a more promising therapeutic method.
Argon knife from the advantages of the above point of view,this technology has been in endobronchial therapy can completely replace the high-frequency electrical burn and may also be substantially replace laser therapy,endobronchial treatment of the future will become a mainstream technology.

Medsinglong Global Group CO.,Limited are able to offer a range of medical products,such as Ultrasound machine,X-ray machine,cheap Ultrasonic therapeutic apparatus,Dental equipment,Autoclaves,ECG,Blood analyzer,Biochemical analyzer,Vet equipment,Radiation protection equipment and so on.Whether the hospital or clinic,or for personal use,you can find your own favorite products.Our mission is;No the best,only better!We are ready to serve you.If you have any needs and questions,with Medsinglong Global Group CO.,Limited contact,Contact E-mail:cindy@medicalequipment-msl.com

Monday, December 7, 2015

Pelvic inflammatory disease therapy device parameters and working conditions

Pelvic inflammatory disease therapy device for the treatment of chronic pelvic inflammatory disease,so the treatment parameters and abdominal cavity electrode is particularly strict,so here we have to introduce you!
Intracavitary electrode basic parameters:
1.Pulse frequency: 1000Hz & plusmn; 150Hz;
2.pulse voltage (peak to peak): 100V & plusmn; 20V;
3.The work surface maximum temperature: 38 ℃ ~ 40 ℃;
The endovascular treatment of head and working part dimensions: & phi; 25mm & times; 150mm;
5.Voltage adjustment: 20,grading adjustable;
6.Temperature adjustment: 16,from ambient temperature to a maximum temperature of work surface,grading adjustable.

portable Pelvic inflammatory disease therapy device

The basic parameters of the abdominal treatment
1.Pulse frequency: 1000Hz & plusmn; 150Hz;
2.pulse voltage (peak to peak): 100V & plusmn; 20V;
3.The work surface maximum temperature: 42 ℃ ~ 45 ℃;
4.Temperature adjustment: 16,from ambient temperature to a maximum temperature of work surface,grading adjustable. 5.abdominal therapy in the treatment area: 381.5c㎡

other:
1.Microprocessor LCD display performance should be stable under natural light,at 30cm from the screen,showing the content should be clearly visible.
2.Endovascular treatment head,abdomen treatment pad connector plug with a locking device shall be.

We are Guangzhou Medsinglong Medical Equipment Co., Ltd specialises in pelvic inflammatory disease treatment instrument factory,if you have any questions, please contact us:Email:cindy@medicalequipment-msl.com