Wednesday, July 20, 2016

How to maintain dental phone

1. All high-speed handpiece, handpieces internal bearing device, without regular maintenance lubrication will cause premature bearing failure phone and shorten its life.

2. The day must be of good quality lubricating oil cleaning and maintenance twice, once when work at noon, afternoon work again. If more than 30 minutes of continuous use, you should select the appropriate time for cleaning oiling during treatment. Autoclavable case, we must do a thorough disinfection before cleaning and maintenance. (Recommend using a dedicated oiling machine)

3. From the end of the phone at the inlet of cleaning oiling until the nose section of the oil mist ejected before (about 2-3 seconds).

4. If the phone, no water, please do not use wire to poke, first with three guns from the outlet side to blow inside the phone, the general failure early this method are valid.

5. It is recommended to use a high temperature high pressure disinfection phone method. It must be thoroughly cleaned before disinfection lubrication, such as incomplete cleaning can cause damage to the bearing acceleration. Phone housing portion with ultrasonic cleaning, and the bearing portion sandwich washed thoroughly with detergent.

6. Press the phone when the use of bur on the chuck portion-holding bur weekly cleaning with high-quality lubricating and maintenance, remove residual stolen goods inside the cartridge, if not cleaned on time will cause the clip does not bear the bur failure.

7. wrench phone while on the needle, the needle is inserted into the car phone, the first needle under pressure and then tighten the screw shank, this method prevents the needle and three spring prematurely.

8. Do not use electrolyzed oxidizing water (strongly acidic water) or disinfectant scrub or mobile phone, the phone will cause damage to bearings and O-rings and mobile phone casing discoloration.

9. The pressure in the range of mobile phones: High speed: 1.8-2.2HPA; (except for individual mobile phone brand) low speed: 2.5-3.0HPA. Do not overload. Pressure too easy to damage the bearing or bur fracture.

10. Whether high-speed or low-speed mobile phone handset for different working diameter bur Please note the corresponding speed, or will accelerate the bearing damage.

11.Regularly check the compressor and filter certain cleaning and maintenance.

12. To use the compressed gas is filtered and dried.

13. Straight machine and bending machine every day after use cleaning agent lubrication, machine straight bur win lighter plug, do not force straight cause malfunction. Bender sure the front part of a thorough cleaning and maintenance after use to avoid contamination inside the nose gear and cause premature failure of the conduction movement.

Guangzhou Medsinglong Medical Equipment Co., Ltd are able to offer a range of medical products, such as Ultrasound machine, cheap disposable scalpels, X-ray machine, Dental equipment, Autoclaves, ECG, Blood analyzer, Biochemical analyzer, Vet equipment, Radiation protection equipment and so on. Whether the hospital or clinic, or for personal use, you can find your own favorite products. Our mission is; No the best, only better! We are ready to serve you. If you have any needs and questions, with Medsinglong Global Group CO.,Limited contact, Contact E-mail: cindy@medicalequipment-msl.com

Monday, June 13, 2016

Classification and use laser treatment Introduction

Laser treatment currently on the market at different excitation material is divided into: a semiconductor laser treatment, excimer laser treatment, carbon dioxide laser treatment, helium-neon laser treatment, Nd: YAG laser treatment.

A semiconductor laser treatment: Usually power is relatively small, mainly used for radiation therapy, used for the treatment of individual families, such as the three high laser irradiation therapy.

Second, the excimer laser treatment (English: Excimer laser) is subjected to laser emission means when its molecular ground state transition mixed gas excited by electron beam of inert gas and a halogen gas formed by combining generated. Excimer laser is a cold laser, non-thermal effect, the photon energy wavelength range of 157-353 nm, and the life of tens of nanoseconds, which belongs to ultraviolet light. Excimer laser in medicine is mainly used in ophthalmology, refractive errors of treatment, such as with PRK, LASIK, LASEK and other methods for the treatment of refractive errors, is currently on the clinical application of relatively common, safe, efficient, effective and stable Qu light therapy is not correct.

Classification and use laser treatment

Third, carbon dioxide laser treatment is more common application of the instrument, multi-function, through the non-contact method of treatment cutting, burning, and irradiation of the biological tissue to produce heat-induced coagulation, vaporization, carbonization effect, so as to achieve shorter operative time, less blood loss , wound healing, anti-infection, the use of more extensive sections.

Fourth, the helium-neon laser treatment is mainly used in medical exposure, irritation, inflammation, pain and dilation of blood vessels. It can be used as medicine acupoint irradiation, local irradiation surface; dermatology for the treatment of skin and mucosal ulceration.

Five, Nd: YAG laser treatment, Nd: YAG simplify its English name from (Neodymium-doped Yttrium Aluminium Garnet; Nd: Y3Al5O12) or Chinese called yttrium aluminum garnet crystals activated yttrium aluminum garnet crystals for substance, Nd atoms within the crystal body content of 0.6 to 1.1%, is a solid-state laser, the laser excitation pulse or continuous laser, infrared laser emission wavelength of 1.064 & mu; m.

Press instrument style can be divided into desktop laser treatment, laser treatment and vertical portable laser treatment device, a portable laser treatment mainly for individual users, with physiotherapy treatment; small power desktop laser treatment, physical therapy and doing superficial irradiation skin treatment; vertical power laser treatment, physical therapy can be surgery treatment, such as coagulation, cutting and so on.

If you have any questions, please contact: Email: cindy@medicalequipment-msl.com
Product details, please click:http://www.medicalequipment-msl.com/

Monday, May 16, 2016

High-frequency electric ion therapeutic instrument Introduction

High-frequency electric ion therapeutic instrument, also known as high-frequency electrocautery treatment instrument electrical energy by making high-frequency oscillating frequency electromagnetic waves, when the high frequency oscillation circuit and a tip conductor close to a certain distance on the spark, the size of the spark, the temperature associated with a conductor. When the human body as a conductor, when the high-frequency output of the instrument tip with human skin tissue close to a certain distance, the spark generated by burning effect, at a temperature between 100 ℃ -3000 ℃, such high temperatures can burn the skin superfluous biological vaporization, make permanent lesions disappear, but such a high temperature also has the ability to cut, cut in small blood vessels can also be closed and stop bleeding.

Technical Parameters
Input voltage: 220V & plusmn; 10% / 50Hz
Working environment: 5-40 ℃ Relative humidity: & le; 85%
Power consumption: 10W-66W output frequency: about 1MHz
EDM output temperature: 100 ℃ -3000 ℃
Instrument Weight: 5.5Kg



Treatment range:
Surgical: superficial foreign body removal, sebaceous cysts, perianal abscess, anal fissure, anal fistula, Corn, hemorrhoids, circumcision, rectal polyps, underarm odor and the like.
Skin Branch: various nevi, flat warts, skin neoplasm, acne, sebaceous cysts, rosacea and so on.
Obstetric gynecology: cervical polyps, cervical cancer, leukoplakia and the like.
Medical Cosmetology: freckles, pierced ears, in addition to tattoos.

Comprehensive treatment instrument of human tissues and organs function:
1. solidification effect. Sparks and high temperatures generated by high-frequency electromagnetic waves near the body skin has solidified the role it can in a relatively short period of time at a lower temperature to more distant deep tissue coagulation.
2. hemostasis. 1.5mm diameter vascular effects following better use of its burning coagulation of small blood vessels can be closed so as to achieve hemostasis.
3. The role of vaporization. When higher power density absorbed by the tissue, when the temperature reaches above 2000 ℃, can shrink the tissue surface, dehydration and carbonization. Internal organization and the instantaneous vaporization of water is due to the explosion, the pressure generated by the explosion, the surrounding tissue can generate a lot of empty pores, thereby undermining the vitality of the organization.
4. The cutting action. Vaporization also a role either in contact or not in contact, so that high temperature cracked skin and muscle, thus further cut tissue, to achieve the purpose of the cutting.

If you have any questions, please contact: Email: cindy@medicalequipment-msl.com
Product details, please click:http://www.medicalequipment-msl.com/

Tuesday, April 19, 2016

Dental treatment Troubleshooting

Check the power supply is normal, pressing the up and down around the key, no action chair. Remove the front cover of the patient chair at check circuit control board labeled AC24V, ACl2V terminals, voltage is normal, and then check the gas control switch control loop is not closed, resulting in the control loop can not be connected. Reason: fixed air control switch screws loose, the valve can not be effectively depressed limit switch. Remedy: Readjust distance gas control valves and limit switch to ensure that the rated pressure under the limit switch can be reliably connected to the fastening screws.

Dental treatment for sale

Press the key patient chair up and down before and after, you can hear the sound of relay, but the chair does not move, this phenomenon indicates that the control loop, no problem. Check AC24V, ACl2V normal. Wherein ACl2V control circuit power supply, AC24V for the DC power supply. After checking the rectified voltage, no DC24V output. View check circuit control board found scorch marks near DC24V rectifier bridge rectifier bridge which measures the arms has breakdown, because there is no DC24V, so although the relay pull, but because of the lack of electrical power, so the chair does not work. Analysis of reasons: The first element is the quality, but off, the second motor stall, causing a short circuit. Check the motor continue down the normal, excluding the second reason. Remedy: Since the control circuit printed wiring board near the bridge rectifier has been blown, only replace the rectifier bridge to cause difficulties, decided to replace the entire board. Should be replaced with a new board of the original 1203 chip circuit board mounted to unplug the new board to continue to use the original data store. Remove the wires, connectors and other color-coded according to its original position and connected, power-commissioning work chair.

Pressing on the best dental chair, down, front, back key, the chair does not move nor relay sound. Open the front cover inspection, AC-DC power supply is normal, if the plugs, no loose wiring, gas control switch is turned good. You should check the key signal line is normal. Inspection method: Unplug the control circuit board signal line plug, a wire with a black line termination socket end and the other end on the other electrodes respectively touch the socket, observe whether the relay operation, the corresponding indicator light is illuminated. As compared with the normal signal conductors have a problem, the most likely reason is that the common black line is broken, identify the point of failure can be treated. If during the test relay no action, then the control board is faulty, replace the circuit control board.