Wednesday, July 20, 2016

How to maintain dental phone

1. All high-speed handpiece, handpieces internal bearing device, without regular maintenance lubrication will cause premature bearing failure phone and shorten its life.

2. The day must be of good quality lubricating oil cleaning and maintenance twice, once when work at noon, afternoon work again. If more than 30 minutes of continuous use, you should select the appropriate time for cleaning oiling during treatment. Autoclavable case, we must do a thorough disinfection before cleaning and maintenance. (Recommend using a dedicated oiling machine)

3. From the end of the phone at the inlet of cleaning oiling until the nose section of the oil mist ejected before (about 2-3 seconds).

4. If the phone, no water, please do not use wire to poke, first with three guns from the outlet side to blow inside the phone, the general failure early this method are valid.

5. It is recommended to use a high temperature high pressure disinfection phone method. It must be thoroughly cleaned before disinfection lubrication, such as incomplete cleaning can cause damage to the bearing acceleration. Phone housing portion with ultrasonic cleaning, and the bearing portion sandwich washed thoroughly with detergent.

6. Press the phone when the use of bur on the chuck portion-holding bur weekly cleaning with high-quality lubricating and maintenance, remove residual stolen goods inside the cartridge, if not cleaned on time will cause the clip does not bear the bur failure.

7. wrench phone while on the needle, the needle is inserted into the car phone, the first needle under pressure and then tighten the screw shank, this method prevents the needle and three spring prematurely.

8. Do not use electrolyzed oxidizing water (strongly acidic water) or disinfectant scrub or mobile phone, the phone will cause damage to bearings and O-rings and mobile phone casing discoloration.

9. The pressure in the range of mobile phones: High speed: 1.8-2.2HPA; (except for individual mobile phone brand) low speed: 2.5-3.0HPA. Do not overload. Pressure too easy to damage the bearing or bur fracture.

10. Whether high-speed or low-speed mobile phone handset for different working diameter bur Please note the corresponding speed, or will accelerate the bearing damage.

11.Regularly check the compressor and filter certain cleaning and maintenance.

12. To use the compressed gas is filtered and dried.

13. Straight machine and bending machine every day after use cleaning agent lubrication, machine straight bur win lighter plug, do not force straight cause malfunction. Bender sure the front part of a thorough cleaning and maintenance after use to avoid contamination inside the nose gear and cause premature failure of the conduction movement.

Guangzhou Medsinglong Medical Equipment Co., Ltd are able to offer a range of medical products, such as Ultrasound machine, cheap disposable scalpels, X-ray machine, Dental equipment, Autoclaves, ECG, Blood analyzer, Biochemical analyzer, Vet equipment, Radiation protection equipment and so on. Whether the hospital or clinic, or for personal use, you can find your own favorite products. Our mission is; No the best, only better! We are ready to serve you. If you have any needs and questions, with Medsinglong Global Group CO.,Limited contact, Contact E-mail: cindy@medicalequipment-msl.com